Multipair Individual/overall Screen with Armor and Lead Sheath
Application :
- These cable can be used in cable tray or conduit to connect different types of thermocouple in industrial process controls, refineries, oil and gas plant. Excellent protection against corrosion, humidity and poor vibration resistance.
Specification :
-
Conductor Solid Type applicable KX, EX, JX, TX, NX, KCA, KCB, RCA, RCB, SCA, RCB, BC Insulation PVC, PE, XLPE or LSZH thermoplastic material Individual screen 24 μm aluminium / PETP tape over solid tinned copper drain wire, 0.6 mm Wrapping At least 1 layer of plastic tape Overall screen 24 μm aluminium / PETP tape over 7-stranded tinned copper drain wire, 0.5 mm² Bedding PE, PVC or LSZH thermoplastic material Lead sheath Lead alloy Inner sheath PVC or LSZH thermoplastic material Armor Galvanized round steel wires Outer sheath PVC or LSZH thermoplastic material Color code According to IEC 60584-3 Flame retardancy IEC 60332-1 Flame propagation IEC 60332 cat. C Temperature range -30°C up to 70°C during operation. -5°C up to 50°C during installation -
KCB IS/OS & armored with lead sheath
0.5 mm² :
-
No. of Pairs Insulation Thickness (mm) Bedding Thickness (mm) Lead Sheath Thickness (mm) Inner Sheath Thickness (mm) Diameter of Armor Wire (mm) Outer Sheath Thickness (mm) Nominal O.D. (mm) Weight* (kg/km) 2 0.4 0.9 1.1 0.8 0.9 1.4 17.3 892 4 0.4 1.1 1.1 0.8 0.9 1.4 18.9 1078 6 0.4 1.2 1.1 0.8 0.9 1.5 21.2 1309 8 0.4 1.2 1.2 0.8 0.9 1.5 22.3 1491 10 0.4 1.2 1.2 0.8 1.25 1.6 25.4 1912 12 0.4 1.2 1.2 0.9 1.25 1.6 25.8 2000 16 0.4 1.3 1.3 0.9 1.25 1.7 28.2 2383 20 0.4 1.3 1.3 0.9 1.25 1.7 29.5 2610 24 0.4 1.3 1.4 1.0 1.25 1.8 32.6 3087
0.8 mm² :
-
No. of Pairs Insulation Thickness (mm) Bedding Thickness (mm) Lead Sheath Thickness (mm) Inner Sheath Thickness (mm) Diameter of Armor Wire (mm) Outer Sheath Thickness (mm) Nominal O.D. (mm) Weight* (kg/km) 2 0.4 0.9 1.1 0.8 0.9 1.4 18.0 970 4 0.4 1.1 1.1 0.8 0.9 1.5 20.2 1204 6 0.4 1.2 1.1 0.8 0.9 1.5 22.3 1451 8 0.4 1.2 1.2 0.8 0.9 1.6 24.6 1848 10 0.4 1.2 1.2 0.9 1.25 1.6 26.9 2137 12 0.4 1.3 1.3 0.9 1.25 1.7 28.2 2383 16 0.4 1.3 1.3 0.9 1.25 1.7 30.0 2690 20 0.4 1.3 1.4 1.0 1.25 1.8 32.1 3092 24 0.4 1.5 1.4 1.0 1.25 1.8 35.2 3581
1.0 mm² :
-
No. of Pairs Insulation Thickness (mm) Bedding Thickness (mm) Lead Sheath Thickness (mm) Inner Sheath Thickness (mm) Diameter of Armor Wire (mm) Outer Sheath Thickness (mm) Nominal O.D. (mm) Weight* (kg/km) 2 0.4 1.1 1.1 0.8 0.9 1.4 18.4 1011 4 0.4 1.1 1.1 0.8 0.9 1.5 20.2 1204 6 0.4 1.2 1.2 0.9 0.9 1.6 23.6 1691 8 0.4 1.2 1.2 0.9 1.25 1.6 24.6 1848 10 0.4 1.2 1.3 0.9 1.25 1.7 27.5 2244 12 0.4 1.3 1.3 0.9 1.25 1.7 28.2 2383 16 0.4 1.3 1.4 1.0 1.25 1.7 30.2 2781 20 0.4 1.5 1.4 1.1 1.25 1.8 32.5 3154 24 0.4 1.5 1.5 1.2 1.6 1.9 36.5 3982
1.3 mm² :
-
No. of Pairs Insulation Thickness (mm) Bedding Thickness (mm) Lead Sheath Thickness (mm) Inner Sheath Thickness (mm) Diameter of Armor Wire (mm) Outer Sheath Thickness (mm) Nominal O.D. (mm) Weight* (kg/km) 2 0.4 1.1 1.1 0.8 0.9 1.5 19.8 1140 4 0.4 1.2 1.2 0.9 0.9 1.5 22.5 1588 6 0.4 1.2 1.2 1.0 1.25 1.6 25.1 1915 8 0.4 1.2 1.3 1.1 1.25 1.6 26.4 2190 10 0.4 1.3 1.3 1.1 1.25 1.7 29.7 2606 12 0.4 1.3 1.4 1.1 1.25 1.7 30.5 2843 16 0.4 1.3 1.4 1.2 1.25 1.8 32.5 3235 20 0.4 1.5 1.5 1.2 1.25 1.9 35.2 3797 24 0.4 1.5 1.5 1.2 1.6 1.9 39.5 4653
1.5 mm² :
-
No. of Pairs Insulation Thickness (mm) Bedding Thickness (mm) Lead Sheath Thickness (mm) Inner Sheath Thickness (mm) Diameter of Armor Wire (mm) Outer Sheath Thickness (mm) Nominal O.D. (mm) Weight* (kg/km) 2 0.5 1.1 1.2 0.9 0.9 1.5 21.1 1303 4 0.5 1.2 1.2 1.0 0.9 1.5 23.7 1741 6 0.5 1.2 1.3 1.1 1.25 1.6 26.9 2193 8 0.5 1.3 1.3 1.1 1.25 1.7 28.7 2481 10 0.5 1.3 1.4 1.2 1.25 1.7 31.9 2995 12 0.5 1.3 1.4 1.2 1.25 1.7 32.6 3164 16 0.5 1.5 1.5 1.3 1.25 1.9 36.3 3863 20 0.5 1.5 1.6 1.3 1.6 1.9 39.2 4686 24 0.5 1.7 1.6 1.3 1.6 2.0 43.6 5471 - *The number here is just approx. weight. It changes according to the insulation material and the conductor used in different type of extension cable and compensating cable.